RL-20S10 SERVICE MANUAL
PAGE:
3
SAFETY PRECAUTIONS
Leakage Current Hot Check (See below Figure)
Plug the AC cord directly into the AC outlet.
Do not use a line Isolation Transformer during this check.
Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor between a known good earth
ground (Water Pipe, Conduit, etc.) and the exposed metallic parts.
Measure the AC voltage across the resistor using AC voltmeter with 1000 ohms/volt or more
sensitivity.
Reverse plug of the AC cord into the AC outlet and repeat AC voltage measurements for each
exposed metallic part. Any voltage measured must not exceed 0.75 volt RMS, which is,
corresponds to 0.5mA.
In case any measurement is out of the limits specified, there is possibility of shock hazard and
the set must be checked and repaired before it is returned to the customer.
Leakage Current Hot Check circuit
!! Important Safety Notice !!
Many electrical and mechanical parts in this chassis have special safety-related
characteristics.
These parts are identified by in the Schematic Diagram and Replacement Parts List.
It is essential that these special safety parts should be replaced with the same components
as recommended in this manual to prevent Shock, Fire, or other Hazards.
Do not modify the original design without permission of manufacturer.
Summary of Contents for RL-20S10
Page 17: ...RL 20S10 SERVICE MANUAL PAGE 17 BLOCK DIAGRAM Block Diagram...
Page 18: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 37: ...RL 20S10 SERVICE MANUAL PAGE 37 PCB LAYOUT 1 Panel Adapter PCB...
Page 38: ...RL 20S10 SERVICE MANUAL PAGE 38 PCB LAYOUT 2 Control PCB...
Page 39: ...RL 20S10 SERVICE MANUAL PAGE 39 PCB LAYOUT 3 1 Main PCB...
Page 40: ...RL 20S10 SERVICE MANUAL PAGE 40 PCB LAYOUT 3 2 Main PCB...
Page 41: ...RL 20S10 SERVICE MANUAL PAGE 41 PCB LAYOUT 3 3 Main PCB...
Page 42: ...RL 20S10 SERVICE MANUAL PAGE 42 PCB LAYOUT 3 4 Main PCB...
Page 43: ...RL 20S10 SERVICE MANUAL PAGE 43 EXPLODED VIEW 1 Explode View...