304150-1-2 en ma 2012-01
4/8
A safety thermocouple cuts the gas supply if the burner is extinguished. The low flame
of the appliance is pre-adjusted in the factory, it must not be changed.
5. FUNCTIONING / HANDLING
a) Installation/Assembly:
- Unpack carefully the machine from its packaging.
- Place the device on a plane and heatproof surface in a well ventilated place.
- Never place the device near a wall or near a partition makes of combustible materials
even if it is very well isolated.
- A distance of minimum 10 cm with the partition or the wall is necessary.
- Remove the protective film from the machine.
b) First starting
:
During the first use, warm your machine up outside during about 30 min to evacuate
residual smokes of manufacturing oil from the metallic parts. This may emit a slight
smell for a few moments.
First cleaning
Clean the device before the first use. (See 6 Cleaning)
Gas connection
The appliances run on the following gases: Butane G30, Propane G31, Natural gas
G20/G25. The appliances are originally delivered with a Butane/Propane injector corre-
sponding to the category II2E+3+. The connection is made thanks to a thread 1/2.
The heat release rate of the appliance is
GAR 7
7 kW
GAR 12
12 kW
GAR 14
14 kW
GAR 19
19 kW
GAR 21
21 kW
For a use in natural gas, change the injectors ( pilot light (
Ø
45). They are deliv-
ered in a small plastic bag in the package. Screw the venture screw 19 mm.
Connect the appliance to the gas supply pipe, interposing a stop valve which enables
the appliance to be insulated from the rest of the installation.
Check the supply pressure using a manometer when all the burners are lit. It must be
equal to the indications on the rating plate.