VA-3
Jan, 2001
13
HOW TO ENTER THE TOUCH SCREEN CALIBRATION
Turn the instrument on while keeping the [SONG COMPOSER] button pressed.
Note:
When entered the Calibration test, you cannot exit unless you carry out the calibration operation.
To perform this test, a normal pen is required.
Press the left lower corner of each slit with the pen for a few seconds, according to the numbering shown in
the following picture.
When the system recognizes the touch, + will change into 0.
This way, the writing Touch me will appear to show the correct order, so please follow this indication.
During the calibration, do not touch any point except "Touch me". After touching the four points, the calibration
ends and the display will show one of the following displays:
If the calibration fails, the following display appears.
You have to carry out the calibration again.
In case of failure, you have to carry out the calibration again.
HOW TO INIZIALIZE THE FLASH AREA
Turn the instrument on while keeping the [MELODY INTELL.] button pressed.
After a few seconds, the display shows:
FLASH PARAMETER LOAD
WAIT PLEASE
NG. Calibration
Calibration OK
If the loading has been performed correctly, the system exits the test mode automatically, resets and goes back
to the main menu.
Note:
After saving these settings, you have to re-load the VA-3 FACTORY USER PROGRAM and FACTORY
MIDI SET.
HOW TO LOAD THE 6th LANGUAGE
Turn the instrument on while keeping the [VIRTUAL BAND] button pressed.
The display shows:
Insert the floppy disk containing the XXXXXXXX.lan file.
After a few seconds, the display shows:
Turn the instrument off and on again.
Caution:
Loading the 6th language will cause the loss of the Netherlands language.
Example:
USER LANGUAGE CUSTOMIZE
Completed
<<Turn instrument on again>>
USER LANGUAGE CUSTOMIZE
Insert disk, please...