background image

 

Troubleshooting

 

There is no sound

 

 

Check to make sure the attenuators are not rotated too far counterclockwise.

 

 

Check to make sure the speaker cables are not shorted and that the speaker impedance is not less than 4 ohms. If

the speaker cable's + and - wires are shorted, or if speakers of less than 4 ohms impedance are connected, the PC
Limiter Circuit is activated in order to protect the speakers, and the sound may be cut off or distorted.

(PC Limiter Circuit 

 

 

p. 10)

 

 

The Thermal Protection Circuit cuts off the sound if the internal power amp overheats. Stop operation of the

equipment for a while to allow the heat to dissipate sufficiently. (About Rack Mounting 

 

 

p. 13)

* The unit automatically restarts when the temperature of the heat sink falls. However, if the overheating protection

circuit is activated again, check to make sure that the operating environment and the speakers connected to the
amp output connectors conform to the SRA-200 specifications (4 ohms in stereo, 8 ohms with the BTL connection).

(Thermal Protection Circuit 

 

 

p. 12)

 

 

When DC (direct current) is generated in the output sent to the speakers, the DC Detection Circuit cuts off the

sound to protect the speakers. The SRA-200E restarts a few seconds after generation of direct current in the output
ceases.

(DC Detection Circuit 

 

 

p. 12)

 

Noise is coming from the amp itself

 

 

Whenever the temperature of the interior heat sinks exceeds 60˚C, the cooling fan is activated. Although this is

audible, it does not indicate a malfunction.

(About the Cooling Fan/Air Vents 

 

 

p. 13)

 

Stereo image incorrect (minimal low end, extreme left-right spread, etc.)

 

 

Is the MODE switch on the rear panel set to "BTL?"

 

 

Set the MODE switch to "STEREO" when using the SRA-200E in STEREO mode.

(MODE Switch 

 

 

p. 7)

(Stereo Connection/BTL Connection 

 

 

p. 8)

 

 

Check to make sure the HOT and COLD of the Channel A and B inputs have not been connected in reverse (make

sure the polarity is correct especially with the screw terminals).

 

 

Check to make sure that you haven't mistakenly reversed the polarity when connecting the speaker cables.

 

The volume is difficult to adjust with the attenuator.

 

 

Use the INPUT LEVEL switch on the rear panel to select the input sensitivity (+4 dBm/-10 dBm) that matches the

system you are using.

 

14

Summary of Contents for SRA-200E

Page 1: ...er The SRA 200 features an internal Limiter Circuit This provide protection against unpleasant sound and damage to speakers resulting from clipping in the amp New ECOS High Efficiency Amplifier Techno...

Page 2: ...ould be taken so that objects do not fall and liquids are not spilled into the enclosure through openings The product should be serviced by qualified service personnel when The power supply cord or th...

Page 3: ...becoming entangled Also all cords and cables should be placed so they are out of the reach of children Never climb on top of nor place heavy objects on the unit Never handle the power cord or its plug...

Page 4: ...etergent Afterwards be sure to wipe the unit thoroughly with a soft dry cloth Never use benzine thinners alcohol or solvents of any kind to avoid the possibility of discoloration and or deformation Ad...

Page 5: ...to attain the proper output level About the Limiter p 10 3 PROTECTION Indicator This lights when the protection circuits are in operation When this indicator is lit sound from the speakers is cut Stop...

Page 6: ...en input is balanced and connect with quarter inch phone type when the input is unbalanced Check the pin assignments of other devices before connecting 3 INPUT Terminals Check the pin assignments of o...

Page 7: ...terminals for connecting speakers To avoid the risk of electric shock do not touch the terminals while the amp is on Please refer to Precautions When Connecting and Switching on the Power p 10 7 Cool...

Page 8: ...each SRA 200E In this mode Channel A and Channel B are bridged internally by means of a BTL connection BTL stands for Balanced Transformer Less and is a method in which the phase of one chan nel is i...

Page 9: ...e sure that the outputs of the mixer and other devices do not overload the system The input impedance of a single SRA 200E itself is 10 kiloohms with balanced or unbalanced input The total input imped...

Page 10: ...o allow shorting in the speaker cables PC Limiter Circuits see below Once the connections have been completed turn on power to your various devices in the order specified By turn ing on devices in the...

Page 11: ...ing and damage to the equipment do not use such cables Contacts for the INPUT connectors are wired in parallel This makes it convenient when a parallel connection is desired Parallel Connection p 9 Ho...

Page 12: ...formation on rack mounting the SRA 200E see Notes on Heat Dissipation p 13 The unit automatically restarts when the temperature of the heat sink falls However if the overheating protection circuit is...

Page 13: ...back to the intakes If there is no way to keep the rear panel of the amp away from the rack then make sure the rack has an opening or fan installed for ventilation of the heated air that builds up dur...

Page 14: ...ection Circuit p 12 When DC direct current is generated in the output sent to the speakers the DC Detection Circuit cuts off the sound to protect the speakers The SRA 200E restarts a few seconds after...

Page 15: ...t sensitivity 4 dBm IHF A weighted Damping Factor 125 or greater 8 ohms load 1 kHz Channel Separation 65 dB or greater 8 ohms load 1 kHz 50 W DIN audio weighted Slew Rate 11 V micro sec or greater ste...

Page 16: ...16 Dimensions 16 15 16 19 13 1 16 1 15 16 1 3 4 5 16 1 1 5 8 1 4...

Page 17: ...el 5 INPUT Connector 6 Jack 6 Terminals 6 INPUT LEVEL Switch 7 LEVEL Indicator 5 Limiter 10 MODE Switch 7 8 Muting Circuit 12 Parallel Connection 9 PC Limiter Circuit 10 POWER Indicator 5 POWER Switch...

Page 18: ...17 Diagorou Street Nicosia CYPRUS TEL 02 66 9426 DENMARK Roland Scandinavia A S Nordhavnsvej 7 Postbox 880 DK 2100 Copenhagen DENMARK TEL 039 16 6200 FRANCE Roland France SA 4 Rue Paul Henri SPAAK Pa...

Reviews: