12
Sep.2003
15.
Return the bender to the center, and verify that the seven-segment LED
indicates “00”.
fig.test2
16.
Verify that the value of each rotary control changes from “00” through
“7F”.
fig.test6
Also verify that detented rotary controls stop at the detent, and indicate a
value of “40”.
fig.test4
17.
Verify that the value of each slide control changes from “00” through
“7F”.
fig.test6
18.
Operate the EXPRESSION PEDAL and verify that the value changes from
“00” through “7F”.
fig.test6
19.
Turn off the power of the PCR. Then turn it on again to start it up in
normal operating mode, and verify that each key will sound.
20.
While playing the keyboard, press the HOLD PEDAL and verify that
notes are held.
21.
Turn off the power of the PCR.
22.
Use a USB cable to connect the PCR’s USB connector to your computer,
turn on the power of your computer and the PCR to start it up in normal
operating mode.
23.
Verify that the computer recognizes the PCR.
24.
Press the [V-LINK] button, play the keyboard, and verify that sound is
produced.
25.
Press the [EDIT] button, press the [SYSTEM] key of the keyboard, press
the [8] key of the keyboard, and then press the [ENTER] button three
times.
26.
When the seven-segment LED indicates “1”, turn off the power of the
PCR to end the procedure.
fig.test5