background image

Advanced Communication Module - Installation Guide                                                  
43

 

 

Quick 

Key 

Parameter 

Provision for optional functionality 

Defining the Network Control Parameters   

From the Dialer menu [5], press [0][4] to enter the Network Control 
parameters Menu. 
 

Quick 

Key 

Parameter 

[5][0][4] 

This option contains parameters that 
specify counters for the ACM to establish 
a connection with the network.  
Provision for optional functionality  

Defining ACM Special Functions 

From the Dialer menu [5], press [0][4] to enter the Network Control 
parameters Menu. 
 

Quick 

Key 

Parameter 

[5][0][5] 

The ACM Special function menu enables 
you to perform special operations of the 
ACM. This option is applicable for ACM 
with dedicated features that are 
customized per project (e.g. performing 
remote upgrade of the ACM). 
A confirmation beep is heard in the 
keypad, indicating that the command was 
successfully sent to the ACM, followed by 
the following message: “SPECIAL 
MESSAGE ACTIVATED
”. 
Default: 001 
Range: 001-255
 

 

Viewing ACM Version and Parameters 

Quick 

Key 

Parameter 

[5][0][6] 

This menu is used to view the ACM 
hardware and software configurations.  
The information includes 4 parameters as 
follows: 

 

ACM MAC Address 

 

ACM Software Version 

 

ACM Hardware Version 

Summary of Contents for ProSYS ACM

Page 1: ...c ce e e e e e e ed d d d d d d d C C C C C C C Co o o o o o o om m m m m m m mm m m m m m m mu u u u u u u un n n n n n n ni i i i i i i ic c c c c c c ca a a a a a a at t t t t t t ti i i i i i i io o o o o o o on n n n n n n n M M M M M M M Mo o o o o o o od d d d d d d du u u u u u u ul l l l l l l le e e e e e e e F Fo or r u us se e w wi it th h R Ro ok ko on ne et t s s S Se ec cu ur ri it ...

Page 2: ...Advanced Communication Module Installation Guide 29 ...

Page 3: ...1 Defining MS Connection Type 11 Defining ACM Parameters 13 Defining the ACM Control Parameters 15 Defining the Network Control Parameters 16 Defining ACM Special Functions 16 Viewing ACM Version and Parameters 16 E MAIL Report 17 Events Report Over IP 18 Getting ACM IP Address 18 Appendix A IP Address Table 19 Appendix B Port Table 19 Appendix C Common Terms and Definitions 20 Technical Specifica...

Page 4: ... ProSYS over TCP IP and provides Ethernet and Fast Modem Interface ACM Encryption is of the SSL TLS type The module can be simultaneously accessed by multiple clients and seamlessly connects to Upload Download software thus enabling remote access and monitoring ACM versions include ACM Basic includes RS485 and Ethernet interfaces ACM Basic Modem includes Ethernet interfaces plus fast modem interfa...

Page 5: ...Supports simultaneous multiple channel Ethernet communication Selected events may be reported to two different email addresses Security Manager can receive security events while installer receives technical indications only Embedded web server with application links into the ProSYS control panel Supports dynamic network addressing DHCP Module firmware is remotely upgradeable when a new version is ...

Page 6: ... Before connecting the ACM calculate and check that the power drawn by the ACM together with all accessories connected to the ProSYS is within the power supply current range Add a power supply module if required 1 Mount the ProSYS main board inside the BOX as described in the Installer manual 5IN128IM 2 Attach the 4 plastic spacers using the provided plastic screws to the ProSYS main holes shown i...

Page 7: ...34 Advanced Communication Module Installation Guide Figure 2 ACM Layout with Spacers ...

Page 8: ...s connected to the BUS 2 pins configuration The ACM U D channel is disabled and a local U D connection to the ProSYS Bus is enabled NOTE Sending information from the panel via the ACM is functioning normally 1 pin default Local U D connection to the ProSYS Bus is disabled and the ACM channel is enabled DFLT Used to restore the default software provided by the manufacturer e g when remote software ...

Page 9: ...peed ON 100 Mbps OFF 10 Mbps SERIAL 1 optional Green Indicates ACM communication with a device via the optional RS232 serial port 1 SERIAL 2 optional Green Indicates ACM communication with a device via the optional RS232 serial port 2 GOOD LINK USB optional Green Indicates communication between the ACM and a device connected to the optional USB port POWER Red Indicates communication status between...

Page 10: ... Yellow Indicates either enabled or disabled local U D connection to the ProSYS ON Local U D is enabled and ACM U D channel is disabled OFF Local U D is disabled and ACM U D channel is enabled PCMCIA IN optional Green Indicates presence of PCMCIA card PCMCIA READ optional Yellow Indicates communication between the ACM and PCMCIA card COMM 485 optional Red Indicates communication status via an opti...

Page 11: ...om the ProSYS installer menu enter the ADD Delete option Quick Key 7 1 2 Press 9 3 to access the ACM module option 3 Use the key to select either NONE no ACM or ACM1 ACM installed 4 Press to confirm your selection Defining MS Connection Type Connection between the ProSYS panel and the monitoring station MS is configured via the Dialer Menu 1 From the ProSYS installer menu access the Dialer menu 5 ...

Page 12: ... IP address that identifies the receiver on the network Default 192 168 001 010 5 1 1 1 3 PORT 1 MS The MS port address of the receiver on the network Default 03010 5 1 1 1 4 CHANNEL 1 MS Defines the type of connection to the MS 5 1 1 1 4 1 INTERNAL PSTN The reporting to the monitoring station will be performed by the telephone line connected to the ProSYS See quick key 5 1 1 1 1 5 1 1 1 4 2 EXTER...

Page 13: ...rotocol supports the Modbus TCP IP protocol by default Default 00502 5 0 2 4 PORT 2 ACM AUX Provision for optional functionality 5 0 2 5 PORT 3 ACM AUX Provision for optional functionality 5 0 2 6 SUBNET IP MASK The definition of the network portion of the IP address This location must be configured that all IP addresses up to and including the local gateway are allowed Default 255 255 255 0 5 0 2...

Page 14: ...PDATE POR S The port address that the ACM turns to during the process of software upgrading Default 00080 5 0 2 0 More 5 0 2 0 1 D IP MASK U The IP address from which a connection to the ACM can be established via the U D software Default 0 0 0 0 5 0 2 0 2 NET NAME ACM A text name used to identify the ACM module over the network Default acm Range 16 characters of any type 5 0 2 0 3 IP 1 DOMAIN NAM...

Page 15: ...ined by quick key 5 0 2 1 Default NO 5 0 3 2 D CONFIGURATION ACM U Defines the authorization type when using the U D software application over the Ethernet network Disabled Full Control View Only optional functionality User Control optional functionality Installer Control optional functionality Default Full Control 5 0 3 3 CONFIGURATION 1 ACM AUX Defines the authorization type when using the recei...

Page 16: ...trol parameters Menu Quick Key Parameter 5 0 5 The ACM Special function menu enables you to perform special operations of the ACM This option is applicable for ACM with dedicated features that are customized per project e g performing remote upgrade of the ACM A confirmation beep is heard in the keypad indicating that the command was successfully sent to the ACM followed by the following message S...

Page 17: ...ced Communication Module Installation Guide Quick Key Parameter ACM Project Number If a communication trouble with the ACM occurs the COMMUNICATION TROUBLE message appears and 3 beeps are heard from the keypad ...

Page 18: ...2 MAIL Defines whether the events defined for telephone FM 2 are reported to e mail 2 as well or not Default No 5 7 5 3 MAIL IP ADDRESS The IP address of the ACM mail server Default 192 168 001 253 5 7 5 4 MAIL SMTP PORT The port address of the ACM SMTP mail server port used to send messages Default 00025 5 7 5 5 PORT 3 MAIL POP The port address of the ACM POP3 mail server port used to retrieve e ...

Page 19: ...e ACM will enable storing of unlimited amount of events over Ethernet resources which can be used for backup and analysis Quick Key Parameter 5 7 6 1 ENABLE Provision for optional functionality 5 7 6 2 LOG IP ADDRESS E Provision for optional functionality 5 7 6 3 LOG IP PORT E Provision for optional functionality Getting ACM IP Address In some installations the ACM IP address might be configured t...

Page 20: ...Advanced Communication Module Installation Guide 47 4 Press to confirm the desired ACM IP address appears on the LCD ...

Page 21: ...1 5 0 2 8 Mail IP Address 192 168 001 253 5 7 5 3 Event Log IP Address 192 168 001 020 5 7 6 2 DNS 1 SERVER IP 192 168 100 251 TBD DNS 2 SERVER IP 192 168 100 252 TBD NTP SERVER IP 192 168 000 060 5 0 2 0 5 U D IP MASK 000 000 000 000 5 0 2 0 1 Appendix B Port Table Description Default Programming Location to Configure User Programming MS Port 03010 5 1 1 1 2 2 ACM U D Port 03000 5 0 2 2 ACM AUX 1...

Page 22: ...by dots e g www rokonet com Domain Name Telecommunications networking protocol a standard computer interconnection method with a data rate of 100 megabits per second The original specification requires coaxial cable as the communications medium but costs have been reduced through the employment of simple paired wires Ethernet Number that uniquely identifies each computer on the Internet IP Address...

Page 23: ...he same network A subnet can be used to increase the bandwidth on the network by breaking up the network into portions or segments Subnet WANs are built to provide communication solutions for organizations or people who need to exchange digital information between two distant places The main purpose of a WAN is to provide reliable fast and safe communication between two or more places Nodes with l...

Page 24: ...perating Temperature 0 55 C Storage Temperature 0 85 C Ordering Information Description Part Numbers ACM Basic version RP128AB0100A ACM Basic Modem RP128AA0100A Customer Information RTTE COMPLIANCE STATEMENT Hereby Rokonet Electronics Ltd declares that this equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC ...

Page 25: ...ation under this warranty shall not include any transportation charges or costs of installation or any liability for direct indirect or consequential damages or delay Seller does not represent that its product may not be compromised or circumvented that the product will prevent any persona injury or property loss by burglary robbery fire or otherwise or that the product will in all cases provide a...

Page 26: ...ited Kingdom Tel 44 1527 576 765 Fax 44 1527 576 816 e mail info rokonet co uk Italy Tel 39 02 392 5354 Fax 39 02 392 5131 e mail info rokonet it Israel Tel 972 3 9637777 Fax 972 3 9616584 e mail info rokonet co il Brazil Tel 55 11 3661 8767 Fax 55 11 3661 7783 e mail rokonet rokonet com br All rights reserved No part of this document may be reproduced in any form without prior written permission ...

Reviews: