7.0 Connecting of exhaustion
An exhausting unit of sufficient exhausting capacity (see the
table) is necessary for a proper functioning of the machine.
Always operate machine only with running exhausting !
Start the machine and the exhausting unit all at once !
Minimal exhausting capacity of exhaustion device
making of
exhaustion
diameter
of exhausting
nozzle [mm]
dry particles
v
min.
= 20m/s
[m
3
/hod]
wet particles
v
min.
= 28m/s
[m
3
/hod]
lower exhausting
-
120
815
1 140
Fried
80
362
507
upper exhausting
CPS
100
565
792
lower + Fried
120 + 80
1 177
1 647
altogether
lower+ CPS
120 + 100
1 380
1 932
For connecting use a flexible exhausting hose of adequate diameter.
The lower exhaustion is lead out in the left side machine part.
Wooden waste must be liquidated eco-friendly - not to worsen the environment.