![Roiscok RP208KCL Manual Download Page 18](http://html1.mh-extra.com/html/roiscok/rp208kcl/rp208kcl_manual_1478649018.webp)
HIT [#] TO CONFIRM
Exit user function status
Depress [*] twice to exit user function state. Then the Power LCD will be lit on, which means it is in
normal status now.
3.13 Exit a error operation
When operate incorrectly, depress [*] to cancel and then operate again.
3.14 Keypad alarm
RP208CN Keypad (RP208KCL) provides 3 groups emergency keys, which can be pushed at
anytime, and the police, fire department, or medical assistance is required. Emergency Alarm is
defaulted as silence alarm.
Press 1 and 2 simultaneously, and for at least two seconds, will activate a Panic Alarm.
Press 4 and 5 simultaneously, and for at least two seconds, will activate a Fire Alarm.
Press 7 and 8 simultaneously, and for at least two seconds, will activate a Medical
Emergency.
3.15 Entry delay and exit delay
The security system must incorporate in and from the premises without causing inadvertent
alarms. A delay period was chosen during your system’s installation to provide suitable time to
allow for your entry and exit. Entry/Exit Delays can be set by programming, and it’s defaulted as 30
seconds. To change the delay time, refer to 6.5.3 of Chapter 6.
3.16 Trouble and display
When the keypad sends out three short beep regularly, indicating that the system exists some
troubles. When get rid of the troubles, the system will restore to normal status and stop beeping.
Troubles include Battery Low, AC power, No Clock, No Communication, No Siren etc. Press [*]
+[3] to search on the LCD.. Depress [←][→] to check the last or the next event.
The troubles displayed as follows:
LCD Display
Trouble
MAIN
:
LOW BATT
Battery Power low
RP248CN User’s and Installer’s Manual