11
4.7. Advanced features of the Rointe system
The Rointe system includes four advanced functions. To activate or deactivate one of the functions
below, press the
button to access the settings menu. Use the
buttons to scroll through
the menu until you find the
POWER
submenu. Press the
button to access the submenu:
1. Open Windows
2. Balance
3. Adaptive mode
By accessing each of them, you can activate or deactivate its operation. Once selected, press the
button and use the
buttons to activate or deactivate the function.
Press the
button once more to confirm the option.
4.7.1. OPEN WINDOWS function
The Rointe system has the OPEN WINDOWS
function activated as a default. This function is
activated when the sensor detects that there has been a temperature decrease of 4°C in a period
of 30 minutes. The OPEN WINDOWS mode is activated for two hours. When the OPEN WINDOWS
mode is active, the radiator will be in ANTI-FROST mode at 7ºC.
4.7.2. BALANCE function
The
BALANCE
submenu causes the product to work in Manual mode with a constant temperature
of 19ºC. Once selected, the product returns to the main screen, with the temperature set at 19ºC and
the
MANUAL
function icon activated.
4.8. Wi-Fi pairing
The Wi-Fi submenu allows you to enable / disable the connection and perform pairing with a device.
Selecting the option “pair the product” will create its own network to which you can connect your
device.