4
2. Rointe towel rails installation
2.1. Mounting instructions
Inside the packaging you will find a fixing kit. Please find the instructions below:
Inside the box/packaging you will find a mounting kit:
1. Choose the right part of the wall.
2. Place the mounting stencil on the wall, marking the places for the holes.
3. Remove the stencil and make the holes in the wall.
4. Insert the rawl plugs in the holes made.
5. Screw the four metallic fasteners to the wall with the 6.3 x 50 mm screw.
6. Screw the four metallic cylinders to the product (see Figure 1).
7. Insert what you have assembled in Section 6 into the metallic fastener and fix well with the 2.9
x 9.5 mm stud bolt.
NO.
ELEMENT
1
10 mm Rawl Plug
2
2 Metallic fastener
3
Screw 2.9 x 9.5mm
4
Screw 6.3 x 50mm
5
Metallic cylinder
6
Product
2.2. Connecting instructions
The connection must be carried out in compliance with the current safety regulations. This appliance
is intended to be permanently connected to a fixed water installation.
If possible, the appliance must be installed away from draughts (windows, doors) or anything else that
might interfere with heat dissipation. In this way, it will provide the best thermal comfort. Place any
object that could impede air circulation (furniture, armchairs) 50 cm from the front of the appliance.
The appliance must not be placed in front of or directly below a fixed electric socket. The lower part
must be at least 15 cm above the floor.
5
6
5
4
3
2
1