9
CIRCE
OVAL
EN
Iindicator
LED
Temperature
Iindicator
LED
Temperature
2 LED
Led 1: ON
Led 2: ON
Led 3: OFF
Led 4: OFF
Led 5: OFF
Led 6: OFF
18ºC
3 LED
Led 1: ON
Led 2: ON
Led 3: ON
Led 4: OFF
Led 5: OFF
Led 6: OFF
21ºC
4 LED
Led 1: ON
Led 2: ON
Led 3: ON
Led 4: ON
Led 5: OFF
Led 6: OFF
24ºC
5 LED
Led 1: ON
Led 2: ON
Led 3: ON
Led 4: ON
Led 5: ON
Led 6: OFF
27ºC
6 LED
Led 1: ON
Led 2: ON
Led 3: ON
Led 4: ON
Led 5: ON
Led 6: ON
30ºC
3.4. Consumption identification
The last temperature indicator LED will flash to indicate the heating element is active and the product
is consuming energy.
3.5. Keypad lock
By pressing the and keys together for 3 seconds, you can lock/unlock the control panel keypad.
If any key is pressed while the panel is locked, all the LEDs will flash twice.
For safety reasons, the on/off button
will respond even if the panel is locked. To switch the
product on or off when the panel locked, press and hold the button
for 3 seconds.
3.6. MAX POWER mode
The MAX POWER mode activates the towel rail heating element to maximum power continuously
regardless of the sensor reading. To activate this function from the control panel, press the button
. You can also activate this mode, even when the product is switched off.
Pressing
once will activate this mode for 15 minutes. If you press (X) again within the next two
seconds, the next period (30 minutes) will be activated. Consecutive presses will activate the
following periods as shown in the table below: