background image

ENGLISH

 

 

 

 

INTRODUCTION

 

• 

Before using your new dehumidifier, please carefully  read  through  the 
following  instructions.  Keep this booklet in a safe place for future refer- 
ence.

 

• 

After removing the packaging, make sure that the appliance is in good 
condition.

 

• 

Do not allow children to play with the packaging  materials as there is risk 
of suffocation.

 

 

SAFETY INFORMATION

 

1. 

Please  read  the  operating  instructions  carefully be-  fore using your 
dehumidifier  for  the  first  time                  and keep them in a safe place.

 

2. 

Never immerse the appliance in water or other  liquids.

 

3. 

Place the unit on a stable flat surface to avoid loud noises and vibrations.

 

4. 

Never operate the appliance if a cable or connector has been damaged, 
after  appliance malfunction  or if   the appliance was dropped or otherwise 
damaged.

 

5. 

The appliance may only be repaired by qualified personnel, improper 
repair  work  can  be  a  source  of considerable danger for the users.

 

6. 

Pull                                         out  the  power  plug  before  transporting  it  and/or before cleaning.

 

7. 

Operate       the  appliance  only  at  the  voltage    specified on the rating  label.

 

8. 

The device may not be connected to a power strip with other household 
appliances.

 

9. 

Use the appliance only in the household and only for the purpose it was 
developed for.

 

10. 

Do not operate this unit near heating appliances  and flammable or 
dangerous objects.

 

11. 

If the dehumidifier is operated in a room with gas  driven devices, the 
room must be aired regularly and often.

 

 

Summary of Contents for R-9610

Page 1: ...ENGLISH R 9610 Dehumidifier Instruction Manual Thank you for choosing our product For proper operation please read and keep this manual carefully ...

Page 2: ...vibrations 4 Never operate the appliance if a cable or connector has been damaged after appliancemalfunction orif theappliancewasdroppedorotherwise damaged 5 The appliance may only be repaired by qualified personnel improper repair work can be a source of considerabledangerfortheusers 6 Pull out the power plug before transporting it and or before cleaning 7 Operate the appliance only at the voltag...

Page 3: ...smoke during start up or if you can see the smoke immediatelydisconnect thepower plug and contact yourdealer 20 The unit should be installed with a minimum distance of 50cmfrom thewall or other obstacles WARNING Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer The appliance shall be stored in a room without continuously operating ig...

Page 4: ...vicecentre 3 The partial or total non respect of the safety instructions in the present instruction manual will automatically release of any type of respon sibilityincaseofmalfunctionofthemachineorinjuriestopersonsorani mals 4 In case of manipulation repairing or any modification of the machine made by unqualified persons or in case of improper use the guarantee will be automatically cancelled COM...

Page 5: ...and falls to the tank the dry air flows through the inner system but becomeswarm INSTALLATION Empty the water tank before every use of the device Duringtheoperationkeepthedoorandwindowsclosedtoconserveenergy Putthedevicestablyasthefollowingphotoinstructs atleast20cmfrom the front backandtheleft rightandatleast50 cmfromthetop ...

Page 6: ...ENGLISH COMPONENTS Continuous ...

Page 7: ...nction aswell To cancel the timer set up press the timer button twice continuously after confirming setup Internaldryingfunction pressthekeytostart thefunction Fan press the key to choose high or low fan speed Display screen in auto dehumidifying or cloth dry mode it will indicate the actual room humidity You can also set the humidity from setting humidity In timer mode itindicatesthesettingtime ...

Page 8: ...er range is from 1to24hoursandyoucanincreaseit1hourbyeverypress Theunitwill turn off when your timer setting terminates During this setting and if no otherkeyis pressed hold the key for 5s and your setting will be conserved whilethetimer light will switchon TIMER ON While the unit is connected with power but not in use press Timer to start thefunction Thenpress Humiditysettingkey Timingincreasing ...

Page 9: ...andthefan will work at the set speed If the room s humidity is lower than the set humidityby 5 thecompressorwillstopbutthefanwillworkatthesetspeed Theinitial humidity value is50 CLOTH DRY MODE CONTINUOUS MODE During this mode the device will work regardless of the room s humidity Thecompressor will work and fanwill workinhighspeed Thefanspeed is adjustable ...

Page 10: ...ke the images below Note before putting back the water tank please ensure the float is flexible 2 Continuous drainage Thewatercanbedrainedcontinuouslybyconnectingawaterpipeintheback theinnerdiameteris9mm Pleasecheckif thepipeisstablyconnectedwith the drainage mouth to avoid water flowing out Note please ensure that the water pipe will not be too long usually 1 more 1 5m and the height cannot surpa...

Page 11: ...lugiftheunitwillnotbeusedforalongtime Donotusechemicalsolventsuchasalcohol gasoline benzenetoclean the device Ifthewatertankgets moldy cleanitwithasoft cloth Use a wet cloth to clean the device do not use chemical solvents Cleanthefilterwithwateratleasteverytwoweeks Noneedtousehotwaterorchemicalsolvents ...

Page 12: ...ut the tank into the unit Operation temperature is too low or too high Operation temperature range is 5 35 Dehumidifying doesn t work Operation temperature or humidity is too low In dry season the dehumidifying effect will not be so obvious Isairoutletorairinlet blocked Clean theairoutletor air inlet No outlet air Is filter blocked Clean the filters Too loud noise Isthedevicetiltedornot stable Put...

Page 13: ...ature The purpose of the dehumidifier is to pump off the unpleasant high humidity in daily life and dry the wet things But it can t be used to keep extreme low temperature Defrost procedure Please note if the ROOM temperature is less than 24 the unit will start defrost function 24 C no defrost 18 23 C 2hours dehumidify then 5minute defrost cycle 12 18 C 25minute dehumidify then 5minute defrost cyc...

Page 14: ...d waste collection centre or to a dealer providing this service Disposing of a household appliance separately avoids possible negative consequences for the environment and health deriving form inappropriate disposal and enables the constituent materials to be recovered to obtain significant savings in energy and resources As a reminder of the need to dispose of household appliances separately the ...