1. This machine is set with safety unit, when the handle does not fasten the cover or the cutter seat
is not fastened, the motor cannot turn, so as to ensure safety for the user.
2. When disassembling or assembling the juicer, press the upper of feed port of the cover with
your hand, then force the handle to slide in or out of cover slot.
3.When disassembling juicing net, first remove the cover and residue barrel, then turn the middle
ring up to 30 degrees by holding juicing nozzle with your hand, and take up, the juicing net will
automatically leave the rotor.
4. In order to avoid damage, before using, first check power supply for compliance with rated
voltage.
5. Clean all parts able to disassemble (refer to the section of "maintenance and cleaning").
6. When assembling, please carefully read the diagram of "name and position of main
components".
7. Please carefully read the "attentions" before using.
※
Juicing
1. Before using, please confirm the button switch of the main machine in stop state, in this way, in
case assembly is not completed, starting the main machine can be avoided, so unnecessary
damage for persons or property avoided.
2. Before juicing, first confirm juicing net and rotor clutched in position, and no hard contact
between juicing net cutter and transparent cover. Put the transparent cover on, put the handle
into the cover slot, then turn on the machine.
3. For using, assemble according to the diagram of "name and position of main components". Turn
on power supply, press switch to let the machine run no-load for 5 sec. Put prepared vegetable
or fruit into feed port of the juicer, press with the pushing bar, evenly, hard and slowly, juice of
the vegetable or fruit can be found, original, fresh, good for health.
4. Note: when pressing food with the pushing bar, force shall be even or indirect, pressing force
shall not be more than 1 kg, no too sudden force, otherwise, juicing effect will be reduced.
※
Operating time
This machine is designed with button switches of O grading, I grading, II grading (O for stop, I for
weak grading, II for strong grading). For juicing, select strong grading, for operating time, after
operating for 1min, stop for 1min, then use again. After the above operation is performed for three
times, stop for 15 min, do not operate until the motor is cooled, in this way, service life of this