Gas Leaks are recognizable by the smell
If you suspect that there is a gas leak, close the cylinder valve. Open the window and ventilate the room.
DO NOT disconnect the pressure regulator. Turn off all the lights and the flames. Turn on the gas slowly and spray the
connections with soapy water or liquid detergent. A gas leak will form bubbles. If there is a leak, close the gas and
inform your local gas dealer.
DO NOT use the heater again until it has been inspected thoroughly by an authorized expert!
NEVER USE matches or other flames to locate the lost!
GENERAL SAFETY INSTRUCTIONS
Cylinder
The heather is suitable for a cylinder of 15 kg maximum capacity.
The replacement of the gas bottle must not be carried out in presence of flames. Use the cylinder only and exclusively
in a vertical position. If a screw regulator is used, make sure that there is a seal and that it is in good condition, if in
doubt replace it. Then place the cylinder in the cylinder compartment holder and hang up the back cover.DO NOT
OVERTURN THE CYLINDER TO MAKE FULL USE OF ITS CONTENT.
Pressure regulators, pipes and hose clamps
CHECK that the rubber tube is fully inserted on the hose connector and is firmly locked by the clamps, in accordance
with UNI-CIG 7140 norms and as showed [G].
Check the conditions of the hose regularly.
If damaged, replace it with one complying with the current 400 mm
length regulations.
Always check the presence of the SEAL GASKET particular [H], fixed
on the pressure regulator connection.
When proceeding to connection, according to UNI-CIG 7131, of B
type fixed pressure regulator 30mbar, compliant to UNI-
CIG 7141, to the cylinder, avoid bending and make bottlenecks on
the rubber tube.
Ventilation of rooms
USE ONLY IN WELL-VENTILATED ROOMS
,
in rooms where the stove is used, adequate ventilation must be
provided.
This ensures the removal of the exhaust combustion products and guarantees the exchange of air.
OPERATING INSTRUCTIONS
1)
Open the gas cylinder valve.
2)
STARTING FROM POSITION "●
" press the adjustment knob for about 10 seconds, and then continuing to press it,
crush one or more times the piezo igniter until the ignition of the pilot flame and the central plate.
3)
When the pilot flame has been switched on continue to hold the knob pressed for 20 seconds, to allow the
thermocouple to heat,
4)
Then rotate the knob to select the desired power level according to the following instruction:
(Small flame) minimum flow, (medium flame) average flow, (large flame) maximum power.
5)
Keep on the knob pressed for 20 seconds; release the knob if the pilot flame remains lit, the heather is regular
working, if the pilot flame goes out repeat the ignition procedure.
6)
To turn off the heater you must close the cylinder valve.
All our heathers are equipped with a safety device (ODS) that operates automatically turning it off if the percentage
of CO2 (Carbon dioxide) exceeds the legal limit.
CAUTION
Stuck "in the low position" the control knob, cancels the intervention of the safety devices;
Be careful to always keep the control knob from returning to "high" position of rest.