August.2019
■
Waveform comparison by using different Cgs capacitances
(
With protection circuits
)
Finally, the measured waveforms when all the Vgs protection circuits are applied are shown in Figure 35. All the abnormalities
during turn on and turn off disappeared, therefore, Cgs is not needed.
Figure 35. Cgs comparison
(
SCT3040KR, with protection circuits
)
Rg=10
Ω
No Cgs
2.2nF
3.3nF
4.7nF