2/11
User
’s Guide
BM1Z102FJ-EVK-001
© 2020 ROHM Co., Ltd.
No. 62UG074E Rev.001
2020.04
AC Pow er supply
Oscillo scope
M ulti m eter
V
Operation Procedure
1
Necessary Equipment
(1) AC power supply (90 Vac to 264 Vac, 10 W or more)
(2) Oscilloscope
2
Connect to Each Equipment
(1) Set the AC power supply to 90 Vac to 264 Vac power supply off.
(2) Connect the output pin (ACOUT-pin, COMMON pin) to Oscilloscope (Insulation isolated).
(3) Connect the pin of the power supply (CN1) to AC power supply output with pair of wires.
(4) Connect the Multi-meter to DCOUT-pin and GND-pin
(5) AC power supply turn on.
(6) Confirm the output waveform synchronized with the AC voltage.
(7) The DCOUT terminal outputs about 1/100 voltage with the DC voltage after the diode rectification.
Caution
:
To avoid the electrical shock , please keep Oscilloscope probes being isolated.
Figure 2. Diagram of How to Connect