8
/18
© 2021 ROHM Co., Ltd.
No. 64UG054E Rev.001
2021.10
User’s Guide
BD93F10MWV-EVK-001 (Stand-Alone)
(Change configuration of the PD contracts)
Note: The configurations of SW_VMAX, SW_VMIN, and SW_PMIN are stored upon power-up.
Dynamically changing the DIP
switches will not change the configuration during operation.
Please do the following procedures to set the new configuration,
settings will be reflected after a power cycle of the EVK.
1.
Turn off VSRC5V if powered up.
2.
Unplug the Type-C cable from the Type-C receptacle and disconnect it from the Source device.
3.
Change SW_VMAX, SW_VMIN, and SW_PMIN according to the requirement.
4.
Power VSRC5V if necessary. The new configuration is stored at power up
5.
Reconnect the Source device to the Type-C receptacle of the EVK via Type-C cable.