![Rohm BD868 0MUF-C Series User Manual Download Page 15](http://html1.mh-extra.com/html/rohm/bd868-0muf-c-series/bd868-0muf-c-series_user-manual_1478246015.webp)
15/35
User
’
s Guide
© 2022 ROHM Co., Ltd.
No. 65UG013E Rev.001
July 2022
Figure 6: Input Voltage Reference Selection via J3
To power ON the EVK set, an external power supply needs to be connected to the banana jacks (see
Figure 1 and Figure 4) that mounted on the MB. Check that the input voltage is in accordance with the range
reported in BD868x0 datasheet (please take care of the correct orientation of the inputs since no reverse
protection is foreseen on the MB).
5.3.
Load Connection
Each output can be tested in light load or in full load.
An external load can be connected to the access points listed in the Table 2 according to the maximum
value, as indicated in the datasheet. As an example, the picture below shows how an electronic load should
be connected to output 3.
Figure 7: Example of electronic load connected to VO3
5.4.
Board Access Points
The EVK board has many access points to ease measurements of PMIC outputs and other signals.
Below is a table that summarize them:
Access point
Description
Summary of Contents for BD868 0MUF-C Series
Page 1: ...BD868x0MUF C Camera PMIC EVK User Guide...
Page 27: ...BD868x0MUF C Camera PMIC User Guide 27 35 2022 ROHM Co Ltd No 65UG013E Rev 001 July 2022...
Page 28: ...BD868x0MUF C Camera PMIC User Guide 28 35 2022 ROHM Co Ltd No 65UG013E Rev 001 July 2022...
Page 29: ...BD868x0MUF C Camera PMIC User Guide 29 35 2022 ROHM Co Ltd No 65UG013E Rev 001 July 2022...
Page 30: ...BD868x0MUF C Camera PMIC User Guide 30 35 2022 ROHM Co Ltd No 65UG013E Rev 001 July 2022...