![Rohde & Schwarz ZNL Series User Manual Download Page 201](http://html.mh-extra.com/html/rohde-and-schwarz/znl-series/znl-series_user-manual_1477893201.webp)
Remote Commands to Perform Measurements with I/Q Data
R&S
®
ZNL
201
User Manual 1178.5989.02 ─ 06
Remote commands exclusive to peak lists
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:ANNotation:LABel[:STATe]
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:COUNt?
...................................................201
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks[:IMMediate]
.............................................. 202
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:LIST:SIZE
.................................................202
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:SORT
...................................................... 202
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:STATe
......................................................203
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:X?
........................................................... 203
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:Y?
........................................................... 203
...........................................................................................204
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:ANNotation:LABel[:STATe]
<State>
This command turns labels for peaks found during a peak search on and off.
The labels correspond to the marker number in the marker peak list.
Suffix:
<n>
.
<m>
Parameters:
<State>
ON | OFF | 0 | 1
*RST:
1
Example:
CALC:MARK:FUNC:FPE:ANN:LAB:STAT OFF
Removes the peak labels from the diagram
Manual operation:
See
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:COUNt?
This command queries the number of peaks that have been found during a peak
search.
The actual number of peaks that have been found may differ from the number of peaks
you have set to be found because of the peak excursion.
Suffix:
<n>
.
irrelevant
<m>
irrelevant
Return values:
<NumberOfPeaks>
Example:
CALC:MARK:FUNC:FPE:COUN?
Queries the number of peaks.
Usage:
Query only
I/Q Analysis