![Rohde & Schwarz TS7124AS Instruction Handbook Manual Download Page 19](http://html1.mh-extra.com/html/rohde-and-schwarz/ts7124as/ts7124as_instruction-handbook-manual_1477710019.webp)
Machine Overview
R&S
®
TS7124AS
19
Instructions Handbook 1179.2948.02 ─ 01
4.2
Rear Tour
Figure 4-3: Rear view of the chamber
1 = Top cover for interior configuration and service (only for expert users)
2 = Numbered RF feedthrough connectors for antennas inside the chamber (only for expert users)
3 = Supply and control panel, see
4 = For optional feedthroughs towards antennas inside the chamber (only for expert users)
5 = Two rear screw holes for mounting brackets (included in delivery)
6 = Two control screws for
7 = Compressed-air supply connector
8 = Grounding terminal (earth ground contact)
The top cover (1) of the chamber is fixed by 16 screws. Only an
is allowed
to open it.
RF feedthrough connectors (2) allow feeding RF signals through the rear chamber wall
to antennas in the chamber. Only an
is allowed to connect, disconnect or
exchange RF cables.
Three openings (4) in the rear wall are provided for optional RF-filtered feedthroughs.
Openings that are not used are covered with blank metal plates. Feedthroughs in these
openings allow feeding control or RF signals through the wall to antennas or to other
equipment in the chamber. Only an
is allowed to exchange the metal plates
or feedthroughs, and to connect, disconnect or exchange cables at the feedthroughs.
Rear Tour