Construction
R&S
®
TS-PSM5
13
User Manual 1178.2809.02 ─ 01
Figure 4-6: R&S TS-PRIO5 contact side (rear of R&S TS-PWA3 chassis)
For more information about the connectors X12 and X14 may be obtained from the
manufacturer PHOENIX CONTACT.
The name of the connector X12 is:
PTSM 0.5/ 4-2.5-H THR R32 - 1770908
The name of the connector X14 is:
SPT 16/ 4-H-10.0-ZB - 1735804
In order to be able to connect a wire to the terminals the terminal’s metal spring must
first be pushed far enough, using a flat-head screwdriver to clear the opening that will
take the wire. To do so a suitable screwdriver must be placed in the left-hand square
opening of the terminal. The metal spring can be pushed to the right by a light lever
action from left to right.
The terminal X12 can take wires with a maximum of 0.5
mm
2
cross-section surface,
while the terminal X14 is suitable for wires with a maximum of 16
mm
2
cross-section
surface.
R&S TS-PRIO5