Configuring the internal baseband source
R&S
®
SMM100A
214
User Manual 1179.1341.02 ─ 05
Segment Restart
Enables/disables the generation of an extra restart marker in the output waveform file.
If additional marker generation is enabled, the existing marker signals in the individual
segment waveform files are not considered, see also
Chapter 4.9.2.4, "Impact of the
"Disable"
No additional marker is generated.
"Marker 1, 2, 3"
Generates a restart marker signal at the beginning of each segment.
The segment begin is defined by the low-high slope of the marker sig-
nal, which applies for switching between two segments and if there is
a segment replay.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:MARKer:ESEGment
4.9.3.4
Multi-segment waveform sequencing
Access:
1. Select "Baseband > ARB > General > Create Multi Segment".
2. In the "ARB: Multi Segment > General" dialog, select an existing list.
3. Select "ARB: Multi Segment > Segment Table" and configure a waveform with
more than one segment.
4. Select "ARB: Multi Segment > Level/Marker/Clock" and adjust the clock settings so
that all segments use the same clock rate.
5. Select "ARB: Multi Segment > General" >
"Create Output File/Create and Load
Output File"
.
6. Select "Sequencing List..."
7. Select "New" or "Load" to load a sequencing list file.
8. Select "ARB: Multi Segment Waveform Sequencing > Sequencing Play List" to cre-
ate a “play list”.
Generating multi-segment waveform files