Remote Control Commands
R&S
®
SMF100A
522
Operating Manual 1167.2319.02 ─ 12
[:SOURce<hw>]:PM<ch>:SOURce
<Source>
Selects the modulation signal source for phase modulation.
Suffix:
PM<ch>
.
1..2
determines the modulation signal channel.
Parameters:
<Source>
LF1 | LF2 | NOISe | EXT1 | EXT2 | INTernal | EXTernal
*RST:
LF1 <PM1>; LF2 <PM2>
Example:
PM1:SOUR LF2
selects the LF generator 2 as internal modulation source in sig-
nal channel 1.
Options:
R&S
SMF-B20
Manual operation:
See
[:SOURce<hw>]:PM<ch>:STATe
<State>
Activates phase modulation.
Note:
Activation of PM deactivates frequency modulation (FM).
Suffix:
FM<ch>
.
1..2
determines the modulation signal channel.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
PM1:STAT ON
activates PM modulation for path 1.
Options:
R&S
SMF-B20
Manual operation:
See
7.13.15 SOURce:POWer Subsystem
This subsystem contains the commands for setting the output level, level control and
level correction of the RF signal.
Other units can also be used instead of dBm:
●
by entering the unit directly after the numerical value (example
:POW 0.5V
)
●
by changing the DEFault unit in the
UNIT
system (see the command
[:SOURce<hw>]:POWer:ALC:PMETer:TYPE
.................................................................... 523
[:SOURce<hw>]:POWer:ALC:REFerence
.........................................................................523
.............................................................................. 524
SOURce Subsystem