Instrument Function
R&S
®
SMC100A
146
Operating Manual 1411.4060.32 ─ 04
The "Dwell Time" set by the user is used as the step time of the sweep. The effective net
dwell time is shorter, reduced by the setting time. This setting time may be greater than
the time specified in the data sheet.
Note:
It is recommended to switch off the GUI update for optimum sweep performance espe-
cially with short dwell times (see
SCPI command:
Trigger Input Slope
Sets the polarity of the active slope of an applied instrument trigger.
This setting affects the INST TRIG input (BNC connector at the rear of the instrument).
"Positive"
The rising edge of the trigger signal is active.
"Negative"
The falling edge of the trigger signal is active.
SCPI command:
5.4 Modulations
5.4.1 Overview
The R&S SMC provides amplitude modulation (AM), frequency modulation, phase mod-
ulation and pulse modulation. In addition, the RF signal can be modulated with internal
modulations waveforms.
The modulations are available for the basic unit (R&S SMC + frequency option R&S SMC-
B10x) without additional equipment options. A standard LF generator is provided for
internal modulation.
Settings for the modulation are made in separate modulation menus. These menus can
be accessed in the block diagram by way of the "Modulation" function block, or by means
of the menu with the same name which is opened using the MENU key.
5.4.1.1
Enabling/Disabling Analog Modulations using the MOD On/Off Key
The MOD ON/OFF key switches the modulations on and off.
MOD ON/OFF
Press the MOD ON/OFF key to enable/disable analog modulations.
Pressing the key again restores the status that was active before the last switch-off. "MOD
OFF" is displayed in the info line of the header next to the "Level" field.
SCPI command:
Modulations