Instrument Function
R&S
®
SMC100A
145
Operating Manual 1411.4060.32 ─ 04
Stop Level - Level Sweep
Sets the stop level.
SCPI command:
Current Level - Level Sweep
Displays the current level.
If "Step" is set, the level for the next level step of the sweep is entered here.
SCPI command:
Shape - RF Level Sweep
Selects the cycle mode for a sweep sequence (shape).
"Sawtooth"
One sweep runs from the start level to the stop level. The subsequent
sweep starts at the start level again, i.e. the shape of sweep sequence
resembles a sawtooth.
"Triangle"
One sweep runs from start to stop level and back, i.e. the shape of the
sweep resembles a triangle. Each subsequent sweep starts at the start
level again.
SCPI command:
Step - Level Sweep
Sets the step width for the individual sweep steps. This entry is effective for all sweep
modes.
With the level sweep, the logarithmic step width is a constant fraction of the current level.
This fraction is added to the current level. The logarithmic step width is entered in dB.
SCPI command:
Dwell Time - Level Sweep
Enters the dwell time and determines the duration of the individual sweep steps.
RF Signal - RF Block