Remote Control Commands
R&S
®
SMBV100B
836
User Manual 1178.4460.02 ─ 03
Parameters:
<Level>
float
Range:
0.02V to 4V
Increment: 1E-4
*RST:
1
Default unit: V
Example:
See
Example "Enabling and configuring the analog output"
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:BIAS:COUPling[:STATe]
<State>
Couples the bias setting of the I and Q signal components.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
See
Example "Enabling and configuring the analog output"
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:BIAS:I
<I>
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:BIAS:Q
<Q>
Specifies the amplifier bias V
bias
of the respective I or Q component.
The value range is adjusted so that the maximum overall output voltage does not
exceed 4V, see
"Maximum overall output voltage"
Parameters:
<Q>
float
Range:
-3.6V to 3.6V
Increment: 1E-4
*RST:
0
Default unit: V
Example:
See
Example "Enabling and configuring the analog output"
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:OFFSet:I
<I>
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:OFFSet:Q
<Q>
Sets an offset V
offset
between the inverting and non-inverting input of the differential
analog I/Q output signal.
The value range is adjusted so that the maximum overall output voltage does not
exceed 4V, see
"Maximum overall output voltage"
SOURce Subsystem