General Instrument Functions
R&S
®
SMBV100B
516
User Manual 1178.4460.02 ─ 03
10.2.2.1
Global Connectors
The R&S
SMBV100B is equipped with User x interfaces which can be freely assigned
a selection of signals and which can be configured as both inputs and outputs.
A common threshold and input impedance is effective for all trigger and clock signal
inputs provided at the User connectors. The settings influence the custom digital mod-
ulations, the generation of waveforms or multicarrier signals, and all digital standards.
The R&S
SMBV100B is also equipped with Inst Trig connector. The instrument trigger
setting influences all sweeps and is effective in the List mode.
See
Chapter 6.10, "Varying the RF Signal in List or Sweep Mode"
gives an overview of the signals that can be applied to and output at
the User connector.
Table 10-1: Mapping control signals to the User x connectors
Connector
Direction
Assigned Signal
Remark
User x
Input
"Global Trigger"
"Global Clock"
"Global Next Segment"
"Baseband Sync In"
"Data"
"BER Data"
"BER Clock"
"BER Data Enable"
"BER Restart"
Option: R&S
SMBVB-K80
User x
Output
"Baseband Marker 1/2/3"
"Baseband Sync Out"
"Symbol Clock"
"Lev Att"
"Burst Gate"
"Hop"
"CW/Mod"
"Triggered"
"BER TestGen Data"
"BER TestGen Clock"
"BER TestGen Data Enable"
"BER TestGen Restart"
Option: R&S
SMBVB-K80
User 5
Output
"Manual Trigger"
10.2.2.2
Trigger, Marker, Clock and RF Connectors
overview of the current mapping of the logical signals to the corresponding connectors.
Configuring the Global Connectors