![Rohde & Schwarz SMBV100B User Manual Download Page 217](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881217.webp)
Configuring the Internal Baseband Source
R&S
®
SMBV100B
215
User Manual 1178.4460.02 ─ 03
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:SEQuence:SELect
Trigger Example
Displays an example of a multi-segment waveform. The currently enabled trigger and
next segment mode are considered. After the instrument is switched on, the graph of
the last loaded waveform is displayed.
Note:
The curves plotted in this dialog box are textbook examples, "not measured"
waveforms. They are intended to visualize the trigger and next segment settings more
clearly.
Remote command:
n.a.
3.7.4
How to Create and Work with the Multi-Segment Waveform Files
This section provides step-by-step instructions on how to configure and use the multi-
segment settings. The
shows the essential stages of multi-segment wave-
form configuration, together with the corresponding user interface dialogs and if appli-
cable, the corresponding file extensions. Perform the necessary settings, enable the
signal generation, and provide trigger signal.
Figure 3-27: Basic workflow for generation of multi-segment waveforms
Generating a multi-segment waveform file (basic workflow)
1. In the "ARB > Create Multi Segment > General" dialog, select "New List" to create
an empty list.
2. Use the "ARB: Multi Segment > Segment Table > Append" function to add two or
more waveform files.
3. In the "ARB: Multi Segment > Level/Clock/Marker" dialog, adjust the "Level",
"Clock", and "Segment Marker" settings.
4. Select the "ARB > Multi Segment > General > Output File" and enter filename.
5. Select "ARB > Multi Segment > General > Save List" to store the configuration file.
6. Select "ARB > Multi Segment > General > Create Output File" or "Create and Load
Output File" to create and load the multi-segment waveform.
7. Select "ARB > Multi Segment > General > State > On".