Configuring the Internal Baseband Source
R&S
®
SMBV100B
168
User Manual 1178.4460.02 ─ 03
datory tags are added and the data is packed into the
WAVEFORM
tag. As result, the
waveform file
SICO.wv
is generated.
This example follows the general principle of creating of a waveform manually, using
the tag file format. The
illustrates this general workflow.
Figure 3-13: Principle of creating a waveform manually
The following steps outline how to create the waveform file
SICO.wv
:
1. Calculate the sine and cosine values, e.g. use the
SICO.cpp
program.
The result is stored in the file
SICO.txt
.
Figure 3-14: Contents of SICO.txt: first column Sine (I), second column Cosine (Q)
2. Convert the values from the file
SICO.txt
into binary format consisting of 16-bit
signed integer numbers. The numeric range between –1.0 and +1.0 corresponds to
the modulation range of the waveform 16-bit D/A converter of -32767 to +32767.
Using the Arbitrary Waveform Generator (ARB)