![Rohde & Schwarz SMBV100A Manual Download Page 659](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_manual_1477734659.webp)
Remote Control Commands
R&S
®
SMBV100A
642
Operating Manual 1407.6062.32 ─ 08
Parameters:
<Mode>
FIXed | VARiable | VATTenuated
FIXed
The settings are fixed and cannot be changed.
Single ended:
IQ:OUTP:POW:PEP
= 1V.
Differential:
IQ:OUTP:POW:PEP
= 2V.
VARiable
The settings can be changed (command
VATTenuated
Enables a precise digital attenuation of the signal. The level of the
baseband and the RF signal is attenuated by the value set with
the command
*RST:
FIXed
Example:
SOUR:IQ:OUTP:MODE VAR
SOUR:IQ:OUTP:ANAL:POW:PEP 2V
[:SOURce<hw>]:IQ:OUTPut:POWer:DATTenuation
<DAttenuation>
The level of the baseband and the RF signal is attenuated by this value.
Parameters:
<DAttenuation>
float
Range:
-3.522 to 80
Increment: 1E-3
*RST:
0
Default unit: dB
Example:
SOUR:IQ:OUTP:MODE VATT
SOUR:IQ:OUTP:POW:DATT 10dB
The level of the baseband and RF signal is attenuated with 10dB.
[:SOURce<hw>]:IQ:OUTPut:TYPE
<Type>
This command selects the output type.
Parameters:
<Type>
SINGle | DIFFerential
SINGle
The I/Q-signal components are output single-ended.
DIFFerential
The I/Q-signal components are output differential.
*RST:
SINGle
Example:
IQ:OUTP:TYPE DIFF
the I/Q-signal components are output differential.