Remote Control Commands
R&S
®
SMBV100A
515
Operating Manual 1407.6062.32 ─ 08
Parameters:
<Sequence>
AUTO | RETRigger | AAUTo | ARETrigger | SINGle
AUTO
The waveform is output continuously.
RETRigger
The waveform is output continuously. A trigger event (internal or
external) causes a restart.
AAUTo
The waveform is output only when a trigger event occurs. After the
trigger event the waveform is output continuously. Waveform out-
put is stopped with command
SOUR:BB:ARB:TRIG:ARM:EXEC
and started again when a trigger event occurs.
ARETrigger
The waveform is output only when a trigger event occurs. The
device automatically toggles to RETRIG mode. Every subsequent
trigger event causes a restart. Waveform output is stopped with
command
SOUR:BB:ARB:TRIG:ARM:EXEC
and started again
when a trigger event occurs.
SINGle
The waveform is output only when a trigger event occurs. After the
trigger event the waveform is output once to the set sequence
length (
SOUR:BB:ARB:TRIG:SLEN
). Every subsequent trigger
event causes a restart.
*RST:
RETRigger
Example:
BB:ARB:SEQ AAUT
sets the "Armed_auto" trigger mode; the device waits for the first
trigger (e.g. with
*TRG
) and then generates the signal continu-
ously.
Marker Settings
....................................................515
................................................516
..................................................516
.................................................517
........................................517
.................................517
[:SOURce<hw>]:BB:ARB:TRIGger:OUTPut<ch>:MODE
<Mode>
The command defines the signal for the selected marker output.
SOURce Subsystem
Summary of Contents for SMBV100A