Remote-Control Commands
R&S
®
SMBV-P101
106
User Manual 1176.9787.02 ─ 05
6.13 Clock Settings
[:SOURce<hw>]:BB:GNPR:CLOCk:MODE
....................................................................... 106
[:SOURce<hw>]:BB:GNPR:CLOCk:MULTiplier
................................................................. 106
[:SOURce<hw>]:BB:GNPR:CLOCk:SOURce
.................................................................... 106
[:SOURce<hw>]:BB:GNPR:CLOCk:SYNChronization:EXECute
..........................................106
[:SOURce<hw>]:BB:GNPR:CLOCk:SYNChronization:MODE
............................................. 107
[:SOURce<hw>]:BB:GNPR:CLOCk:MODE
<Mode>
Enters the type of externally supplied clock (
EXTernal
).
When
MCHip
is used, a multiple of the chip clock is supplied via the clock connector
and the chip clock is derived internally from this.
Use the command
[:SOURce<hw>]:BB:GNPR:CLOCk:MULTiplier
to set the multi-
plier.
Parameters:
<Mode>
CHIP | MCHip
*RST:
CHIP
Manual operation:
See
[:SOURce<hw>]:BB:GNPR:CLOCk:MULTiplier
<Multiplier>
Specifies the multiplier for clock type "Multiplied" (
MCHip
) in the case of an external clock source.
Parameters:
<Multiplier>
integer
Range:
1 to 64
*RST:
4
Manual operation:
See
[:SOURce<hw>]:BB:GNPR:CLOCk:SOURce
<Source>
Selects the clock source.
Parameters:
<Source>
INTernal | EXTernal
*RST:
INTernal
Manual operation:
See
[:SOURce<hw>]:BB:GNPR:CLOCk:SYNChronization:EXECute
Performs automatically adjustment of the instrument's settings required for the selected
synchronization mode.