Test configuration
R&S
®
SMBV-K361, R&S
®
SMBVB-K361, R&S
®
SMW-K361
22
User Manual 1178.6591.02 ─ 09
●
TC4: "Poor Reception" test pre-configured via
eCallT3_T4.txt
and
eCallUrbanCanyon.ant_pat
.
"Set to Default" does not reset the specified files. You can reset all files to the pre-
defined using "Set to Default" in "Vehicle Simulation" configuration dialog, see
ter 5.2, "Vehicle simulation setting"
on page 17. For general reset, you can also exe-
cute "Set all to Default" to the left at the bottom.
Test Case 7
One measurement step comprises off signal, signal on, until the DUT can acquire the
signal again. You can also let amplify the signal by a configurable gain.
5.6
Advanced settings
The following section specifies the settings to speed up the tests or to loosen the strict
conformance limits and conditions. Note, that all default settings are according to the
specification. For tests according to the specification, keep the advanced settings
unchanged.
The following parameters are configurable.
................................................................................... 23
..................................................................................... 23
Advanced settings