Rohde & Schwarz RTM3000 Series Getting Started Download Page 1

R&S

®

RTM3000

Oscilloscope

Getting Started

 

1335908402
Version 07

(=Sèâ2)

Summary of Contents for RTM3000 Series

Page 1: ...R S RTM3000 Oscilloscope Getting Started 1335908402 Version 07 S 2...

Page 2: ...9 0 Email info rohde schwarz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are...

Page 3: ...nuals and instrument help 14 2 2 Data sheet and brochure 15 2 3 Calibration certificate 15 2 4 Release notes and open source acknowledgment 15 3 Preparing for use 16 3 1 Lifting and carrying 16 3 2 Un...

Page 4: ...Contents R S RTM3000 4 Getting Started 1335 9084 02 07 4 1 2 Other connectors on the front panel 23 4 2 Side view 24 4 3 Rear view 25 5 Contacting customer support 27...

Page 5: ...u of potential dangers and gives instructions on how to prevent personal injury or damage caused by dangerous situations Safety information is provided as follows In Chapter 1 1 Safety instructions on...

Page 6: ...self Use the instrument handles to move or carry the instrument Do not use the mounted accessories instead of the handles Accessories are not designed to carry the weight of the instrument To move the...

Page 7: ...necting to power and grounding The mains power supply input of the instrument complies with overvoltage cate gory II It has to be connected to a fixed installation used to supply energy con suming equ...

Page 8: ...ceed the value specified in the data sheet Observe all voltage and current ratings of the instrument the probes and the accessories Limits and ratings are marked on the products and listed in the data...

Page 9: ...tive measures to pre clude direct contact with the measurement setup Do not touch exposed connections and components when power is applied Switch off the test circuit while connecting and disconnectin...

Page 10: ...thout rated measurement category For measurements performed on circuits not directly connected to mains for example electronics circuits powered by batteries and specially protected secondary circuits...

Page 11: ...nductor terminal Connect this terminal to a grounded external conductor or to protective ground This protects you against electric shock should an electric problem occur 1 2 Labels on the product Labe...

Page 12: ...d result in death or serious injury if not avoi ded CAUTION Potentially hazardous situation Could result in minor or moderate injury if not avoided NOTICE Potential risks of damage Could result in dam...

Page 13: ...Safety and regulatory information R S RTM3000 13 Getting Started 1335 9084 02 07 1 5 Korea certification class A A Korea certification class A...

Page 14: ...s an introduction to remote control a complete description of the remote control commands with programming examples and information on maintenance and instrument interfaces Includes the contents of th...

Page 15: ...an overview of the instrument and deals with the specific characteristics See www rohde schwarz com brochure datasheet rtm3000 2 3 Calibration certificate The document is available on https gloris ro...

Page 16: ...ng material Use it when transporting or shipping the product later 3 Using the delivery notes check the equipment for completeness 4 Check the equipment for damage If the delivery is incomplete or equ...

Page 17: ...work that supplies residential buildings Class A equipment is intended for use in industrial environments It can cause radio disturbances in residential environments due to possible conducted and radi...

Page 18: ...t Prevent overheating as follows Keep a minimum distance of 10 cm between the fan openings of the prod uct and any object in the vicinity Do not place the product next to heat generating equipment suc...

Page 19: ...To unmount the product from a rack 1 Loosen the screws at the rack brackets 2 Remove the product from the rack 3 If placing the product on a bench top again unmount the adapter kit from the product Fo...

Page 20: ...and heel strap combination During operation if the firmware observes a serious unexpected disturbance e g due to ESD it resets some hardware components and initiates a new alignment to ensure proper i...

Page 21: ...ING The fuse is part of the main power supply Handling the fuse while the power is on can lead to electric shock Before changing the fuse a Set the switch on the power supply to position 0 b Disconnec...

Page 22: ...Front panel of R S RTM3000 with 4 input channels 1 Display 2 Horizontal and vertical setup controls 3 Trigger settings action and analysis controls 4 Analog input channels BNC 5 External trigger inpu...

Page 23: ...set from 5 V to 5 V For channel connectors the input impedance is selectable the values are 50 and 1 M The maximum input voltage is 400 V peak 300 V RMS at 1 M input impe dance and 30 V peak 5 V RMS a...

Page 24: ...bes to the oscilloscope channel Square wave signal for probe compensation Ground connector for probes USB type A 10 USB 2 0 type A interface to connect a mouse or a keyboard or a USB flash drive for s...

Page 25: ...to D7 and D8 to D15 The maximum input voltage is 40 V peak at 100 k input impedance The maxi mum input frequency for a signal with the minimum input voltage swing and medium hysteresis of 800 mV Vpp...

Page 26: ...ce frequency USB type B 2 USB 2 0 interface of type B device USB for remote control of the instrument LAN 3 8 pin connector RJ 45 used to connect the instrument to a Local Area Network LAN It supports...

Page 27: ...duct contact our customer support center A team of highly qualified engineers provides support and works with you to find a solution to your query on any aspect of the operation program ming or applic...