Parameters:
<Polarity>
POSitive | NEGative
POSitive = high active
NEGative = low active
Parallel Buses - Decode Results
The commands to query results of decoded parallel clocked and unclocked buses are
similar and described together in this chapter..
.............................................................................................439
..........................................................................................439
..............................................................................439
............................................................................439
............................................................................440
..........................................................................440
.............................................................................440
...........................................................................440
..............................................................................440
...........................................................................440
BUS<b>:PARallel:FCOunt?
BUS<b>:CPARallel:FCOunt?
Returns the number of decoded frames.
Suffix:
<b>
.
1..4
Selects the bus.
Note: SPI/SSPI and UART protocols occupy two bus lines.
Return values:
<FrameCount>
Total number of decoded frames.
Usage:
Query only
BUS<b>:PARallel:FRAMe<n>:DATA?
BUS<b>:CPARallel:FRAMe<n>:DATA?
Returns the data words of the specified frame.
Suffix:
<b>
.
1..4
Selects the bus.
Note: SPI/SSPI and UART protocols occupy two bus lines.
<n>
*
Selects the frame.
Return values:
<FrameData>
List of decimal values of data words
Usage:
Query only