Remote Control
R&S
®
RTM20xx
332
User Manual 1317.4726.02 ─ 01
Parameters:
<State>
ON | OFF
ON
Cursor lines keep their relative position to the waveform.
OFF
Cursor lines remain on their position on the display if the scaling
is changed.
*RST:
OFF
CURSor<m>:RESult?
Returns the measurement result for count, mean, RMS, rise and fall time, peak meas-
urements, and burst width. Make sure to set
correctly.
Suffix:
<m>
.
1
The numeric suffix is irrelevant.
Return values:
<Value>
Measurement result
Usage:
Query only
CURSor<m>:XDELta:INVerse?
Returns the inverse time difference between the two cursors (1/
Δ
t).
Suffix:
<m>
.
1
The numeric suffix is irrelevant.
Return values:
<DeltaInverse>
Range:
-1,00E+026 to 1,00E+026
Increment: 0.1
*RST:
0
Default unit: 1/s
Usage:
Query only
CURSor<m>:XDELta[:VALue]?
Returns the time difference between the two cursors (
Δ
t).
Suffix:
<m>
.
1
The numeric suffix is irrelevant.
Return values:
<Delta>
Range:
-1,00E+026 to 1,00E+026
Increment: 0.1
*RST:
0
Default unit: s