background image

Safety Information

R&S

®

RT-ZF6

3

Manual 1326.3764.02 ─ 02

1

 

Safety Information

The product documentation helps you to use the product safely and efficiently.
Keep the product documentation nearby and offer it to other users.

Safety information warns you about the potential dangers and gives instructions
how to prevent personal injuries or damage caused by dangerous situations.
Throughout the documentation, safety instructions are provided when you need to
take care during setup or operation.

Intended use

The equipment under test (EUT) is a signal quality test and development board,
indented to be used at laboratory or test and measurement areas. These areas
are used for analysis, testing and servicing and where equipment is operated by
trained personnel (EN 61326-1, 3.9).

Operating site

Only use the product indoors, and keep it dry. The product has no casing and is
sensitive to moisture and humidity.

The product is suitable for pollution degree 2 environments where nonconductive
contamination can occur. For more information on environmental conditions such
as ambient temperature, see the specifications.

Installation

Connect only 1000BASE-T1 devices with the clock output according to the
1000BASE-T1 standard.

Electromagnetic emissions

The EUT is considered as a test probe, EN

 

61326-2-1, clause 5.2.4.101, note 1.

Therefore normal operation may increase emissions and/or reduce immunity in
certain applications.

The EUT is an EN 55011 class A equipment. Class A equipment is intended for
use in an industrial environment. There may be potential difficulties in ensuring
electromagnetic compatibility in other environments due to conducted as well as
radiated disturbances.

Summary of Contents for RT-ZF6

Page 1: ...R S RT ZF6 Frequency Converter Manual Manual Version 02 1326376402 JUÎ2 ...

Page 2: ...49 89 41 29 0 Fax 49 89 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are trademarks of the owners Throughout this manual products from Rohde Schwarz are indicated without the symbol e g R S RT ZF6 is indicated as R S RT ZF6 ...

Page 3: ... by trained personnel EN 61326 1 3 9 Operating site Only use the product indoors and keep it dry The product has no casing and is sensitive to moisture and humidity The product is suitable for pollution degree 2 environments where nonconductive contamination can occur For more information on environmental conditions such as ambient temperature see the specifications Installation Connect only 1000B...

Page 4: ...3 m 2 Product Description The R S RT ZF6 frequency converter is a product for compliance testing of the 1000BASE T1 standard It is used in combination with R S RTO R S RTP oscilloscope R S RT ZF2 Ethernet compliance test fixture R S RTO K87 1337 8591 02 R S RTP 1800 6554 02 for 1000BASE T1 compliance tests R S ScopeSuite software For data see the R S RT ZFxx Oscilloscope Test Fixtures Specificatio...

Page 5: ... MHz signal The 10 MHz output is supplied at the BNC connectors X5 and X6 The board is supplied over the USB connector X7 3 Connecting the Board To set up the measurement perform the following steps 1 Check the position of the DIP switches S1 and S2 a S1 all switches OFF b S2 switches 1 4 and 5 OFF switches 2 3 and 6 ON 2 Connect the input X1 to the clock signal of the 1000BASE T1 PHY using dou bl...

Page 6: ...Board R S RT ZF6 6 Manual 1326 3764 02 02 4 Connect the USB port X7 of the frequency converter to a USB port type A of the R S RTO R S RTP or generator or PC A yellow LED lights up if the board is supplied with power ...

Reviews: