background image

R&S®RT-ZC02

 

R&S®RT-ZC03

AC/DC Current Probe

 

User Manual

/ U

ser

 M

anual

Summary of Contents for RT-ZC02

Page 1: ...R S RT ZC02 R S RT ZC03 AC DC Current Probe User Manual User Manual...

Page 2: ...ecifications RT ZC03 6 Specifications RT ZC02 7 4 Operating Instructions RT ZC03 8 9 12 12 12 12 12 13 Operating Instructions RT ZC02 4 1 Switch On 4 2 Zero Adjustment 4 3 Current Measurement 4 4 Auto...

Page 3: ...has been designed for use with DMMs only Using advanced Hall Effect technology the i30s can accurately measure currents with a resolution of 1 mA from 5 mA to 30 A over the frequency range of DC to 1...

Page 4: ...hold the Current Probe anywhere beyond the tactile indicator Before each use inspect the Current Probe Look for cracks or missing portions of the Current Probe housing or output cable insulation Also...

Page 5: ...WEEE compliant This product is designed to be safe under the following con ditions indoor use altitude up to 2000m temperature 0 C to 50 C maximum relative humidity 80 for temperatures up to 31 C decr...

Page 6: ...C typ Output sensitivity 100m V A Frequency range DC to 100 kHz 0 5 dB typ Max slew rate 20 A s typ Response time better than 1 s Working voltage 300 VRMS AC or DC General data Operating temperature 0...

Page 7: ...10 VRMS typ Gain variation 0 15 of reading C typ Output sensitivity 10 1 mV A Frequency range DC to 20 kHz 3 dB typ Max slew rate 20 A s typ Response time better than 5 s Working voltage 300 VRMS AC...

Page 8: ...without notice 4 Operating Instructions RT ZC03 1 2 5 4 7 9 8 6 4 3 1 Jaws 2 Conventional current direction 3 Tactile Barrier 4 Battery cover 5 Battery cover screw 6 Jaw trigger 7 ON OFF switch 8 Aut...

Page 9: ...hout notice Operating Instructions RT ZC02 1 Jaws 2 Conventional current direction 3 Tactile Barrier 4 Battery cover 5 Battery cover screw 6 Jaw trigger 7 ON OFF and range switch 8 Auto zero button 9...

Page 10: ...10 Subject to change without notice Typical performance Plots RT ZC03 20 15 10 5 0 10 100 1000 10000 100000 Frequency Hz Phase Shift in Degrees Relative Gain in db...

Page 11: ...1000A Gain dB 100A CP1005 Phase Response 45 00 40 00 35 00 30 00 25 00 20 00 15 00 10 00 5 00 0 00 10 100 1000 10000 100000 Frequency Hz Phase Shift in Degrees phase 100A phase 1000A 5 Warning To avo...

Page 12: ...ctor en suring a good contact between the closing faces of the jaws Observe and take measurements as required Positive output indicates that the current flow is in the direction shown by the arrow on...

Page 13: ...arantee compliance with the specified technical data The testing is performed with testing equipment that is calibrated to national standards The statutory warranty provisions shall be governed by the...

Page 14: ...rohde schwarz com Service www service rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are tradema...