Instrument Functions
R&S
®
UPP
307
User Manual 1411.1055.32 ─ 10
Range
The possibility of selecting the measurement range allows optimum adaptation to a
voltage range required for a specific measurement task.
As with the switch-over between AC and DC coupling, it is also possible to select
between two options for range setting: either a common setting function for all ranges
of the active channels or independent setting of individual channels.
The reference channel for the Track function is always the active channel. Independent
of this, the inactive channels always remain in the most insensitive range.
To prevent overranging of one or more active channels, the least sensitive range of all
active channels is set by the following manual switch-overs:
●
In Track mode when switching over from Auto to Lowest, or from Fix to Lowest
●
When switching over from Split to Track if the reference channel is set to Fix or
Lowest.
If Split was selected in the operator field above, the range settings can be selected
separately for each activated channel above.
The number of newly displayed operator fields depends on the number of activated
measurement channels.
Remote command:
Chx Range
The possibility of selecting the measurement range allows optimum adaptation to a
voltage range required for a specific measurement task.
As with the switch-over between AC and DC coupling, it is also possible to select
between two options for range setting: either a common setting function for all ranges
of the active channels or independent setting of individual channels, see
It is possible to switch between 3 modes. If all channels have the same setting (Track),
only the text "All Ranges" appears to the left of the selection box.
Configure Analog Analyzer
Summary of Contents for R&S UPP
Page 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Page 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Page 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Page 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...