Remote control commands
R&S
®
RTB2000
423
User Manual 1333.1611.02 ─ 11
15.8.7.2
Bode plot diagram settings
................................................................................................ 424
.............................................................................................. 424
............................................................................................. 425
................................................................................................425
BPLot:GAIN:DATA?
Returns the data of the gain waveform.
Parameters:
<GainData>
Usage:
Query only
BPLot:GAIN:ENABle
Enables the gain waveform for the Bode plot.
Parameters:
<Enable>
ON | OFF
*RST:
ON
Manual operation:
See
BPLot:GAIN:POSition
Sets the vertical position of the gain waveform in divisions.
Parameters:
<WaveformPosition> Range:
-20.0 to 20.0
Increment: 0.1
*RST:
3.0
BPLot:GAIN:SCALe
Sets the vertical scale for the gain waveform.
Parameters:
<WaveformScale>
Range:
0.1 to 20.0
Increment: 0.1
*RST:
20.0
Applications