PRINT TRACE
The
PRINT TRACE
softkey starts the output of all curves visible on the display
screen without auxiliary information. Specifically, no markers or display lines are
printed.
Remote command:
HCOP:ITEM:WIND:TRAC:STAT ON
HCOP:IMM
PRINT TABLE
The
PRINT TABLE
softkey starts the output of all tables and info lists visible on the
display screen without the measurement diagrams and other information lying
behind.
Remote command:
HCOP:ITEM:WIND:TABL:STAT ON
HCOP:IMM
DEVICE
SETUP
The
DEVICE SETUP
softkey opens the dialog where the file format and the printer
can be selected. For details on selecting and configuring printers, and printing out
the measurement results refer to the Quick Start Guide chapter 1, “Preparing for
Use” and chapter “Printing Out Measurement Results”.
Remote command:
HCOP:DEV:LANG GDI;
SYST:COMM:PRIN:ENUM:FIRS?;
SYST:COMM:PRIN:ENUM:NEXT?;
SYST:COMM:PRIN:SEL <Printer>;
HCOP:PAGE:ORI PORT;
HCOP:DEST "SYST:COMM:PRIN";
HCOP:DEST "SYST:COMM:MMEM"
DEVICE 1 / 2
The R&S FSP is able to manage two hardcopy settings independently of each other.
They are selected via the
DEVICE 1 / 2
softkey, which displays also the associated
setting if the
DEVICE SETUP
dialog is open. For details on selecting and configur-
ing printers, and printing out the measurement results refer to the Quick Start Guide
chapter 1, “Preparing for Use” and chapter “Printing Out the Measurement Results”.
Remote command:
--
COLORS
The
COLORS
softkey gives access to the submenu where the colors for the printout
can be selected (see section
“Selecting Printer Colors” on page 4.205
Remote command:
--
COMMENT
The
COMMENT
softkey opens an entry field in which a comment of two lines (60
characters per line) can be entered for screen A or B.
If the user enters more than 60 characters, the excess characters appear on the
second line on the print-out. At any point, a manual line-feed can be forced by enter-
ing the @ character.
The comment is printed below the diagram area. The comment text appears on the
hardcopy, but not on the display screen.
If a comment should not be printed, it must be cleared.
If the instrument is reset by a click on the PRESET key, all entered comments are
cleared.
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...