NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
172
User Manual 1178.5689.02 ─ 06
2.5.12.4
User-Defined Scheduling Settings
The following commands define parameters for the scheduling type "User defined".
CONFigure:NIOT:SIGN<i>:CONNection:UDEFined:UDPattern
........................................... 172
CONFigure:NIOT:SIGN<i>:CONNection:UDEFined:DL[:SET<setNr>]
..................................172
CONFigure:NIOT:SIGN<i>:CONNection:UDEFined:UL[:SET<setNr>]
..................................173
CONFigure:NIOT:SIGN<i>:CONNection:UDEFined:DL:MCSindex?
.....................................174
CONFigure:NIOT:SIGN<i>:CONNection:UDEFined:UL:MCSindex?
.....................................174
CONFigure:NIOT:SIGN<i>:CONNection:UDEFined:FORMat?
............................................ 175
CONFigure:NIOT:SIGN<i>:CONNection:UDEFined:UDPattern
<Pattern>
Selects the pattern of grants sent to the UE.
Parameters:
<Pattern>
DL | UL | DLUL | NOS | DL95
DL
: continuous DL grants
UL
: continuous UL grants
DLUL
: alternating DL/UL grants
NOS
: no scheduling / no grants
DL95
: continuous DL 95
kbps
*RST:
DLUL
Example:
See
Configuring User-Defined Channels
Firmware/Software:
V3.7.20, V3.7.30 added NOS, DL95
Manual operation:
See
CONFigure:NIOT:SIGN<i>:CONNection:UDEFined:DL[:SET<setNr>]
<Subcarriers>, <StartSubcarrier>, <MCSindex>, <Subframes>, <Repetitions>
Configures the downlink user-defined scheduling. Only certain value combinations are
accepted, see
Chapter 2.2.10, "User-Defined Scheduling"
Suffix:
<setNr>
.
1
For future use
Parameters:
<Subcarriers>
SC12 | KEEP
Number of subcarriers (only in the query form of the command)
This parameter is not editable, for the setting, use value "KEEP".
*RST:
SC12
<StartSubcarrier>
0 | KEEP
Start subcarrier (only in the query form of the command)
This parameter is not editable, for the setting, use value "KEEP".
*RST:
0
Command Reference