Modules
R&S
®
OSP
90
User Manual 1178.7100.02 ─ 05
The relay type is monostable (or "failsafe open"). Hence, with no voltage applied to a
relay, no RF connection is provided from terminal C to any of the numbered ports. To
establish an RF connection between C and one of the numbered ports, a continuous
voltage must be applied to the corresponding power terminal of the relay.
The relays are mounted directly into the module's panel and soldered to the module's
printed board, to avoid relay cabling and allow a compact module size.
The switch unit provides power supply and control via a single module bus cable to a
module bus connector on the module's printed board. The module's on-board memory
stores its configuration data.
Figure 3-55: Pinout and block diagram of RF switch module R&S
OSP-B112E
In the module version
.11
with 1 SP6T relay (K1), the relay K2 is not available.
Figure 3-56: Representation of the module on the control screen, with 1 or 2 relays
For operation, see
For remote control, refer to the chapters
R&S
OSP-B112E RF Switch Module