Remote Commands
R&S
®
FSW
765
User Manual 1173.9411.02 ─ 19
CALC:LIM:FAIL?
//Queries the result of the limit check for all ranges.
TRAC:DATA? LIST
//Returns the peak for each range of the SEM measurement as a list.
11.5.7 Measuring Spurious Emissions
All remote control commands specific to spurious emissions measurements are descri-
bed here.
................................................................................. 765
...................................................................................... 765
Configuring the List Evaluation
............................................................................. 773
Performing a Spurious Measurement
................................................................... 775
Retrieving and Saving Settings and Results
.........................................................775
Programming Example: Spurious Emissions Measurement
.................................775
11.5.7.1
Initializing the Measurement
Note that with the R&S
FSW, the spurious measurement must be initialized before you
can start configuring the sweep list or list evaluation.
INITiate:SPURious
This command initiates a Spurious Emission measurement.
Usage:
Event
11.5.7.2
Configuring a Sweep List
The following commands configure the sweep list for spurious emission measure-
ments.
The sweep list cannot be configured using remote commands during an on-going
sweep operation.
Useful commands for configuring the sweep described elsewhere:
●
Remote commands exclusive to spurious measurements:
[SENSe:]LIST:RANGe<range>:BANDwidth[:RESolution]
....................................................766
[SENSe:]LIST:RANGe<range>:BANDwidth:VIDeo
.............................................................766
......................................................................................... 767
.......................................................................................767
[SENSe:]LIST:RANGe<range>:DELete
............................................................................ 767