Remote Commands
R&S
®
FPL1000
682
User Manual 1178.3370.02 ─ 03
Output functions require the option R&S
FPL1-B5 to be installed on the R&S
FPL1000.
........................................................................................682
................................................................................................ 683
OUTPut:UPORt:WTRigger:POLarity
................................................................................ 684
.............................................................................................684
............................................................................................684
DIAGnostic:SERVice:NSOurce
<State>
This command turns the 28 V supply of the BNC connector labeled NOISE SOURCE
CONTROL on the R&S
FPL on and off.
Suffix:
<n>
.
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
0
Example:
DIAG:SERV:NSO ON
Manual operation:
See
OUTPut:IF[:SOURce]
<Source>
Defines the type of signal available at the IF/VIDEO connector of the R&S
FPL.
Parameters:
<Source>
IF
The measured IF value is available at the IF/VIDEO output con-
nector.
The frequency at which the IF value is provided is defined using
the
VIDeo
The displayed video signal (i.e. the filtered and detected IF sig-
nal, 200mV) is available at the IF/VIDEO output connector.
This setting is required to provide demodulated audio frequen-
cies at the output.
*RST:
IF
Example:
OUTP:IF VID
Selects the video signal for the IF/VIDEO output connector.
Manual operation:
See
Setting Basic Spectrum RF Measurement Parameters