![Rohde & Schwarz FPL1000 Series User Manual Download Page 365](http://html.mh-extra.com/html/rohde-and-schwarz/fpl1000-series/fpl1000-series_user-manual_1477826365.webp)
The Spectrum Application (RF Measurements)
R&S
®
FPL1000
365
User Manual 1178.3370.02 ─ 03
For a detailed list of supported sensors, see the data sheet.
Power sensors can also be used to trigger a measurement at a specified power level,
e.g. from a signal generator (see
"Using a Power Sensor as an External Power Trig-
Signal
source
Power
sensor
R&S
®
FPL
Figure 7-34: Power sensor support – standard test setup
Using the power sensor with several applications
The power sensor cannot be used from the R&S
FPL1000 firmware and the R&S
Power Viewer Plus (virtual power meter for displaying results of the R&S NRP power
sensors) simultaneously.
Result display
The results of the power sensor measurements are displayed in the marker table. For
each power sensor, a row is inserted. The sensor index is indicated in the "Type" col-
umn.
Using a Power Sensor as an External Power Trigger
Power sensors can be used to trigger a measurement at a specified power level, e.g.
from a signal generator. For a list of supported power sensors see the data sheet.