![Rohde & Schwarz EX-IQ-BOX User Manual Download Page 367](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982367.webp)
Remote Control Commands
R&S
®
EX-IQ-BOX
352
User Manual 1409.5570.32 ─ 05
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SIGNal<ch>:STATe
<State>
The command activates a signal for transmission selected with
<ch>
.
Parameters:
<State>
OFF | ON
*RST:
OFF
Example:
SOUR1:EBOX:CPRI:RX:SIGN:STAT ON
activates the fist signal for transmission in reciever mode.
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:TX|RX:WARNing?
The command asks if settings have been changed, but not accepted.
Return values:
<Warning>
0 | 1
*RST:
0
Example:
SOUR1:EBOX:CPRI:TX:WARN?
check if changed settings have been accepted.
Response:
1
if settings are not yet accepted,
0
if OK.
Usage:
Query only
Manual operation:
See
9.4.10 CPRI Vendor Data Subsystem
The
VENDor:DATA
command subsystem provides input of user-specific information via
remote control commands.
.............................................................352
..............................................................353
...................................................................353
...............................................................353
[:SOURce<hw>]:EBOX:CPRI:VENDor:DATA<ch>
<Data>
Queries or determines vendor-specific data for transmission, depending on the trans-
mission mode.
Parameters:
<Data>
integer
The value range depends on the word width.
Range:
"depends on other settings" to "depends on other
settings"
Example:
SOUR1:EBOX:CPRI:VEND:DATA 16,#H2A
determine vendor-specific data for transmission.
CPRI Remote Control Commands
Summary of Contents for EX-IQ-BOX
Page 147: ...Protocol Settings R S EX IQ BOX 132 User Manual 1409 5570 32 05 CPRI...