![Rohde & Schwarz EVSG-B1 User Manual Download Page 276](http://html.mh-extra.com/html/rohde-and-schwarz/evsg-b1/evsg-b1_user-manual_1477820276.webp)
Remote Commands
R&S
®
EVSG1000
276
User Manual 1178.6227.02 ─ 06
LLZ_BB_AF_BW_IDDIST_KHZ?
<Bandwidth>
LLZ_BB_AF_BW_IDDIST_KHZ
<Bandwidth>
This command gets or sets the demodulator bandwidth for LF input (AF mode) for ID
and distortion measurement in "ILS LOC" mode.
Parameters:
<Bandwidth>
0_5KHZ | 1_5KHZ | 3KHZ | 5KHZ
Bandwidth
Default unit: kHz
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
LLZ_BB_BW_KHZ?
<Bandwidth>
LLZ_BB_BW_KHZ
<Bandwidth>
This command gets or sets the demodulator bandwidth for LF input (AF mode) in "ILS
LOC" mode.
Parameters:
<Bandwidth>
0.5KHZ | 1.5KHZ | 3KHZ | 5KHZ | 9KHZ | 12.5KHZ | 18KHZ |
25KHZ
Bandwidth
Default unit: kHz
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
LLZ_BB_LFIN_DCOFFSETV?
<DCOffset>
LLZ_BB_LFIN_DCOFFSETV
<Power>
This command gets or sets the reference power for LF input (AF signals only) in "ILS
LOC" mode. This value is used to determine the modulation depth and corresponds to
the DC power of the AF signal.
Parameters:
<Power>
Reference DC power of the AF signal
Default unit: V
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
ILS Localizer (LOC) and Glidepath (GP) Modes