Remote Control
R&S
®
ESRP
713
User Manual 1175.7445.02 ─ 08
Example:
CALC:LIM:ACP:ALT2 30DB, 30DB
Sets the relative limit value for the power in the lower and upper
second alternate adjacent channel to 30 dB below the channel
power.
CALC:LIM:ACP:ALT2:ABS -35DBM, -35DBM
Sets the absolute limit value for the power in the lower and
upper second alternate adjacent channel to -35 dBm.
CALC:LIM:ACP ON
Switches on globally the limit check for the channel/adjacent
channel measurement.
CALC:LIM:ACP:ALT2:STAT ON
Switches on the limit check for the lower and upper second adja-
cent channel.
INIT;*WAI
Starts a new measurement and waits for the sweep end.
CALC:LIM:ACP:ALT2:RES?
Queries the limit check result in the second alternate adjacent
channels.
Usage:
Query only
CALCulate<n>:LIMit<k>:ACPower[:STATe]
<State>
This command switches on and off the limit check for adjacent-channel power mea-
surements. The commands
CALCulate<n>:LIMit<k>:ACPower:ACHannel[:
or
CALCulate<n>:LIMit<k>:ACPower:
ALTernate<Channel>[:RELative]:STATe
must be used in addition to specify
whether the limit check is to be performed for the upper/lower adjacent channel or for
the alternate adjacent channels.
Suffix:
<n>
.
Selects the measurement window.
<k>
irrelevant
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:LIM:ACP ON
Switches on the ACLR limit check.
Manual operation:
See
See
See
Analyzing Results
The following commands analyze and retrieve measurement results for ACLR mea-
surements.
Remote Commands in Spectrum Analyzer Mode