Command Reference
R&S
®
CMW-KM750/-KM751
99
User Manual 1173.9670.02 ─ 05
CONFigure:TDSCdma:MEAS<i>:MEValuation:LIMit:PVTime:YABSolute
<PvTYAbsALimit>, <PvTYAbsCLimit>, <PvTYAbsGLimit>
Defines upper limits (Y-values) for the areas of the power template, see
Parameters:
<PvTYAbsALimit>
Limit area 1
Range:
-80 dBm to 0 dBm
*RST:
-65 dBm
Default unit: dBm
<PvTYAbsCLimit>
Limit area 2
Range:
-70 dBm to 0 dBm
*RST:
-50 dBm
Default unit: dBm
<PvTYAbsGLimit>
Limit area 3
Range:
-70 dBm to 0 dBm
*RST:
-65 dBm
Default unit: dBm
Example:
See
Firmware/Software:
V1.0.4.11
CONFigure:TDSCdma:MEAS<i>:MEValuation:LIMit:PVTime:XRELative
<PvTXRelALimit>, <PvTXRelBLimit>, <PvTXRelDLimit>, <PvTXRelFLimit>,
<PvTXRelHLimit>
Defines the borders (X-values) of the areas of the power template, see
Parameters:
<PvTXRelALimit>
Start of area 1
Range:
-70 chips to -50 chips
*RST:
-60 chips
Default unit: chips
<PvTXRelBLimit>
End of area 1 (and start of area 2)
Range:
-40 chips to -20 chips
*RST:
-33 chips
Default unit: chips
<PvTXRelDLimit>
End of area 2
Range:
-20 chips to -10 chips
*RST:
-13 chips
Default unit: chips
Multi Evaluation Measurement Commands